| MODEL |
16 GH |
24 GH |
32 GH |
| MACHINE SIZE (w/o conveyor) |
|
|
|
| Length (mm) |
192" (4880) |
288" (73155) |
384" (14,630) |
| Width (add 12" for control box) (mm) |
60" (1524) |
60" (1524) |
60" (1524) |
| Height (mm) |
90" (2286) |
90" (2286) |
90" (2286) |
| Weight (approximate) |
5,400 |
7,800 |
10,400 |
| ELECTRICAL SERVICE |
|
|
|
| Standard Electrical Service |
230/460 volts 60 cycle 3 phase |
| Nameplate Amps |
49/24 |
49/24 |
63/31 |
| STEAM REQUIREMENTS |
|
|
|
| BHP Average (Kg/hr) |
15 (265) |
15 (265) |
20 (350) |
| Steam Line |
1" |
1" |
1" |
| Return Line |
1/2" |
1/2" |
1/2" |
| Maximum Pressure (atm) |
125 PSI (9) |
125 PSI (9) |
125 PSI (9) |
| GAS REQUIREMENTS |
|
|
|
| Gas Line |
2" |
2" |
2" |
| Operation Gas Pressure (w.c.) |
8-16" w.c. |
8-16" w.c. |
8-16" w.c. |
| Operation Gas Pressure (millibar) |
24-40 mbar |
24-40 mbar |
24-40 mbar |
| Burner Rating BTU |
800,000 |
800,000 |
1,200,000 |
| Average Usage BTU |
300,000 |
475,000 |
750,000 |
| AVerage Usage Watts |
100,000 |
140,000 |
220,000 |
| VENTILATION REQUIREMENTS |
|
|
|
| Exhaust Duct Size (mm) |
16" (407) |
16" (407) |
16" (407) |
| |
|
|
|
|
|
 |
|  |